Thorough and good educator regarding reasonable options

The sales person was Steve Comfort and not Paul Ash. Steve was knowledgeable and presented a couple options. Also, Steve provided details regarding available rebates. Sales person just left 20 minutes ago. I cannot rate cost/pricing until the estimate is received.


Response from Chud Air Conditioning & Heating:

Thank you for sharing your experience Fran, everyone at Chud appreciates it!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service


Response from Chud Air Conditioning & Heating:

Gary & Linda, thank you for leaving Chud a 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Paul was very thorough in his explanation of services rendered to our systems


Response from Chud Air Conditioning & Heating:

Julie, thank you for the 5 star review, we are grateful that you chose Chud.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fine service

Shane was very polite & informative. He kept me aware of what he was doing & didn't mind my ?'s


Response from Chud Air Conditioning & Heating:

Ara, thank you for the 5 star review, we are grateful that you chose Chud.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service


Response from Chud Air Conditioning & Heating:

The team here at Chud loves to see 5 star reviews! Thank you Bill.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quick response to problem

Thanks for sending technician out. Our electrican came out and said we are only getting half the power from the PECO lines. PECO is aware. Thank again, Julianna McKeeve


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Julianna. It truly means a lot to the Chud team!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!!!

Frank did a great job, very courteous and quick


Response from Chud Air Conditioning & Heating:

Jim, thank you for the 5 star review.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service


Response from Chud Air Conditioning & Heating:

Nicholas, thank you for leaving Chud a 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

We’re always satisfy with Chud’s timely service.


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Julia. It truly means a lot to the Chud team!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service


Response from Chud Air Conditioning & Heating:

5 stars, thank you Bill!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service


Response from Chud Air Conditioning & Heating:

Nicholas, thank you for leaving Chud a 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Paul was excellent, he took the time to explain what he was doing and also did a repair on the system


Response from Chud Air Conditioning & Heating:

Jim, we’ll make sure to pass your kind words along to Paul, who we know will be delighted to read your comments.

  • Overall Experience
  • Quality
  • Price
  • Convenience

good service


Response from Chud Air Conditioning & Heating:

Arnold & Shirley, thank you for the 5 star review, everyone at Chud appreciates it!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Chud pleases!

Great service again


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Chud’s great service

We’re always happy with Chud’s timely arrival and knowledgeable technicians.


Response from Chud Air Conditioning & Heating:

Thank you for sharing your experience Julia! Everyone at Chud appreciates it.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for lower moreland township, pa

Paul A.

Paul A. Job Checkin

1 -18k in living room. 1 system 2-9k in bedrooms. 1 system


Paul T.

Paul T. Job Checkin

Performed preventative maintenance for a high efficiency Goodman ac system. Upon arrival the thermostats were calling for ac. I put both thermostats in the off position. I powered down the system at the furnace and removed the access panels. The evaporator coil’s are clean and in great condition. Tested the drain pan, drain line and condensate pump with several bottles of water to ensure that there were no leaks or clogs. The homeowner stated that he had an issue with the condensate pump overflowing. I tested the condensate pump and checked the internal components and could find no issues with the system. I cleaned the washable air filter but suggested that the homeowner clean the filter using water, let it dry outside the re install it in the system. This will ensure that the filter is completely clean. The blower motor and blower wheel are clean and in great condition. I checked all electrical connections to ensure that they are secure and in good condition. I re attached the access


Paul T.

Paul T. Job Checkin

Performed preventative maintenance for a high efficiency Lennox ac system. Model #13ACD-060-230-01, serial #5805L27188. Upon arrival the thermostat was in the off position. I powered the system down at the furnace and removed the access panels. The evaporator coil’s are clean but in fair condition. The elbows of the evaporator coil are severely rusted. I tested the drain pan and drain line with several bottles of water to ensure that there are no leaks or clogs. I cleaned out the trap and replaced the 16x25x1 air filter chud supplied. I inspected all electrical connections to ensure that they are secure and in good condition. I re attached the access panels and powered the system back up. I called for AC and observed the system starting normally. The healthy climate uv light was replaced last year and is still operating properly. I closed the dampener and powered down the humidifier for the summer. The blower motor amp draw is at a 8.10. The condenser coils are dirty but in good condit


Shane A.

Shane A. Job Checkin

Completed a preventative maintenance on a 13 year old Lennox unit. I changed customer supplied 16x20x1 filter, I took the split temperature and it was only 11. Due to the age of the system the customer just wanted to add refrigerant and see how far that will go. I have a 20 degree temperature difference. And a 8 degree subcooling the system is operating properly. Performed a amperage readings on the compressor 7.04 amps and condenser fan motor 1.0 amps system is operating properly properly at this point


Paul A.

Paul A. Job Checkin

Spoke with both decision makers. Will discuss what our best price is with the general manager. Customer advised they will be paying by check. N/C.


Paul T.

Paul T. Job Checkin

Performed preventative maintenance for a high efficiency Lennox AC system. Model # is missing , serial #5807E04556 . Upon arrival the thermostat was set for heat. I powered down the thermostat and replaced the batteries supplied by the homeowner. I powered the system down and removed the access panel. The evaporator coils are clean and in good condition. Tested the drain pan , drain line and condensate pump to ensure that there are no leaks or clogs. I replaced the #201 air filter supplied by the homeowner. I checked all electrical connections to ensure that they are secure and in good condition. I re attached the access panels and powered the system back up. I called for AC and observed the system starting normally. The condenser coils are clean and in good condition. The condenser amp draws are .63 for the fan and 6.9 for the compressor. The temperature split is at a 19° differential. The system is operating at this time. I presented the homeowner with several solutions to help impro


Paul T.

Paul T. Job Checkin

Performed preventative maintenance for a high efficiency Lennox system. Mode #EL16XC1S036-230B03, serial #5819K08311. Upon arrival the system was turned off at the thermostat. I powered the system down and removed the access panel. The evaporator coil’s are clean and in good condition. I tested the drain pan and drain line with several bottles of water to ensure that there are no leaks or clogs. I replaced the #401 air filter and checked all electrical connections to ensure that they are secure and in good condition. I re attached the access panels and powered the system back up. I called for ac and observed the system starting normally. The condenser coils are clean and in good condition. The condenser amp draws are .73 for the fan and 7.4 for the compressor. The system has a temperature split of 20° differential. The system is operating properly at this time.


Paul T.

Paul T. Job Checkin

2nd floor system located in the attic. Performed preventative maintenance for a Lennox AC system. Model #14ACXS030-230A20, serial #1916E21982. Upon arrival the thermostat was turned off. I powered down the system and removed the access panel. The evaporator coil’s are clean and in good condition. I tested the drain pan and draiN line with several bottles of water to ensure that there are no leaks or clogs. I replaced the air filter size located in the return grill in the hallway. I checked all electrical connections to ensure that they are secure and in good condition. The healthy climate uv bulb is currently burnt out. I re attached the access panels and powered the system back up. I called for AC and observed the system starting normally. The condenser coils are clean and in good condition. The condenser amp draws are .77 for the fan and 4.68 for the compressor. The temperature split is at a 20° differential. 1st floor system located in the basement. Performed preventative mainten


Paul A.

Paul A. Job Checkin

Existing air handler is a 2 ton ICP unit. Outdoor unit is a 1.5 ton ICP unit. R-22 refrigerant. Air handler is 42” tall, 16.5” wide, and 21.5” deep. Homeowner would like the unit on the existing angle iron/wood. Attic opening is 26.5” by 24”. After speaking with the homeowner and verifying the air handler and outdoor unit have separate circuit breakers I prepared 6 options. I advised the homeowner that I will need to verify the new air handler will fit, as the old one is 42” tall. I will schedule a return visit to present the options when both decision makers are home. N/C, estimate.


Shane A.

Shane A. Job Checkin

Completed two preventative maintenance on Lennox units. Manufacturer Lennox Model # CBX32MV-048-230-6-06 Serial # 5811D02403 First unit the temperature split was 19. I made sure the drain line was working. Did a amp check on the condenser fan motor and compressor. The fan motor was a little high because of how dirty the coils is. Changed out 16x20x4 pure air kit. System is operating properly at this point. Lennox Model # XP21-036-230-02 Serial # 5811B15795 Made sure drain and condensate pump was working. Changed 16x25x4 pure air kit. Did a amp check on the condenser fan motor and compressor the fan amperage was high because of the coil being dirty. System is operating properly at this point. After the maintenance I did two coil cleaning on both outdoor units. Per rc customer will be switched to ccm agreement


Shane A.

Shane A. Job Checkin

Customer said their was leak from hvac unit was leaking. After water testing the unit the pan was not pitch properly. Used rubber pad to level the unit properly. Performed a Maintenance the charge is good all parts are very worn and should be replace customer is moving and is not interested in replacing parts or unit. Manufacturer Unico Model # MC3642C Serial # 0311A129715 Manufacturer Lennox Model # HS29-036-2P Serial # 5803L57857


Paul T.

Paul T. Job Checkin

Came out today for a no heat call for a Goodman system model #ARUF37C14AC, serial #1807304934. Another tech was out on 12/13/22 and they found a blown fuse. He replaced it with a popper so the homeowner could reset it if needed. Upon arrival the system was calling for heat and the popper was tripped. I removed the access panels and reset the popper. It Tripp within 3 seconds. I turned the system off at the thermostat and set the blower for auto. I reset the popper again and again it tripped. I advised the homeowner that there is a short in the system somewhere an electrical troubleshooting is needed. I let the homeowner know the price for troubleshooting and explained that if I started today I would only be able to check the indoor unit. I cannot open the electrical compartment of the heat pump due to the rain. The homeowner stated that he would like us to make a return visit on a day when it is not raining so it could be done all at once. See estimate for pricing. No Charge for diagno


Shane A.

Shane A. Job Checkin

Went to a no heat call. Nothing was working when I got their. Took the fuse out put a 3amp popper in system worked just fine. Refrigerant levels where good and all low voltage wiring indoor and outdoor look fine. Also, the emergency heat was working as well. I could not find a reason for the fuse to pop. I left the popper in so if the issue happens again the home owner can reset it until we can come back and fix the issue. M#ARUF37C14AC s#1807304934


Shane A.

Shane A. Job Checkin

Did a maintenance on a high efficiency furnace. Cleaned the flame sensor, cleaned out burner box and the blower motor housing. Did a amp check on the blower motor and inducer motor they both are in range of the furnace. Did a combustion test the ppm was 14 and the o2 was 9. Cleaned off washable filter. M#GMEC961004CN s#2010071987


Shane A.

Shane A. Job Checkin

We will need to return customer has not heat. Board gave me code of open safety device, found one of the roll outs were bad. After that the spark ignition was not working. We will need to replace these parts. Also we will need to change the filter and complete a maintenance 4 16x20x2 filters. M#DCG0721403BXXXAB s#1708542501